详细介绍

size 6, 10

component series 2x

maximum operating pressure 315 bar

maximum flow 75 l/min

features:

direct operated proportional directional valve withoutelectrical position feedback, with external electronics

control of the direction and magnitude of a flow

operation by means of proportional solenoids with central threadand detachable coil

for subplate mounting: porting pattern according to iso 4401

spring-centered control spool

technical data

general

type

4wra

size

610

installation position


any, preferably horizontal

ambient temperature range

°c

-20 … +70

storage temperature range

-20 … +80

weight

kg

26.6

hydraulic

size

610

maximum operating pressure


bar

315

maximum operating pressure

port p

bar

315

port t

210

anschluss a

315

port b

315

maximum flow


l/min

4275

with double flow

l/min

80140

nominal flow

7
15
2630
60

hydraulic fluid 1)


see table

hydraulic fluid temperature range


°c

-20 … +80

preferably

+40 … +50

viscosity range


mm²/s

20 … 380

preferably

mm²/s

30 … 46

maximum admissible degree of contamination of the hydraulicfluid, cleanliness class according toiso 4406 (c) 2)


class 20/18/15 according to iso 4406 (c)

hysteresis


%

≤ 5

range of inversion

≤ 1

response sensitivity

≤ 0.51)additional hydraulic fluids upon request2)thecleanliness classes specified for the components must be adhered toin hydraulic systems. effective filtration prevents faults andsimultaneously increases the life cycle of the components. for theselection of the filters, see www.boschrexroth.com/filter.

hydraulic fluid

classification

suitable sealing materials

standards

mineral oils and related hydrocarbons

hl, hlp

nbr / fkm

din 51524

important information on hydraulic fluids:

for more information and data on the use of other hydraulicfluids please contact us.


electrical

size

610

voltage type


direct voltage

maximum solenoid current


a

2.5

maximum current consumption

of the amplifier

a

1.8

of the amplifier (impulse current)

3

solenoid coil resistance

cold value at 20 °c

Ω

2

maximum hot value

3

actuated time

100

maximum coil temperature 1)

+ 150

power supply


vdc

24

supply voltage range


v

21 … 351)due to the surface temperatures occurring at thesolenoid coils, the european standards iso 13732-1 anden 982 need to be adhered to.