hkw9700-h-g系列热保护器
技术规格书
(technicalspecification)
文件编号:hkw/
part number产品型号 hkw9700-f-h50~150 华恺威专业各类热保护器温度开关与您携手共创美好未来!更多产品请访问官网:www.hkw9700.com
编制
审核
批准
hanfeng
xielihua
lihai
2012-6
2012-6
2012-7
产品用途 hkw9700-f-h型热保护器具有体积小、外壳绝缘、动作灵敏、寿命长等特点,
适用于新能源电池,电机、电源,光灯镇流器、变压器、汽车马达、集成电路及
一般电气设备的过热过流双重保护作用。
hkw9700-f-h thermal protector has small dimension;insulation shell;
sensitive and long life time. its widely use in new energybattery;
motor; power; ballast; transformer;integrated circuitand
electrical e’s overheat and overload doubleprotection.
2 结构特点structural features
hkw9700-f-h系列热保护器是采用一定几何形状的双金属片,无需辅助机构,仅靠双金属片的自身感温和电流热效应,使双金属元件的状态发生快速变化,直接带动触点实现自动切断和接通电路,起到过热、过载保护作用。
hkw9700-f-g thermal protector use unique bimetal and don’tneed more auxiliary parts. using bimetal self-sensing temperatureand current thermal effect to change the bimetal’s shape to controlthe electric circuit cut off or contact on. overheat and overloaddouble protection.
3 安规认证 (certification):cqccqc9
ul e502318
kc zu02105-19001
tuv b1039300001
rohs agc001-001 reachagc001-003
华恺威专业各类热保护器温度开关与您携手共创美好未来!更多产品请访问官网:www.hkw9700.com
地址:惠州市博罗县石湾镇明月二路26号3楼 技术咨询李小姐:
电话:0752-3095516 邮@hkw9700.com
4 产品外形dimension
plastic shell塑壳:20*8*4mm; 铁壳:20*7.8*3.8
contact type动作分为:常开/常闭 normal closed or normalopened
热保护器的外壳 可以配安装支架。optional mounting bracket
5 产品性能performance
5.1额定电流rated power(cos∮=0.7)
dc 12v-12a 24v-8a、ac 250v-5a 125v 7a 可订做10a
5.2断开温度action temp:30℃~150℃; 复位温度reset temp20℃~110℃。
5.3抗拉力试验:产品的引线端应能承受大于或等于20n拉力,导线无断裂、滑出。
tensile test:≥20n,no breaks or slips out of thewire
5.4绝缘电压:insulation voltage
a.产品在断开时的引线之间应能承受ac660v,历时1min而无击穿闪络现象;
in the power off state the insulation voltage between twowires should accept ac660v one minute withoutbreakdown andflashover.
b.产品引线与绝缘外壳之间能承受ac1800v,历时1s而无击穿闪络现象;
the insulation voltage between the wires and shell shouldaccept ac1800v 1 second withoutbreakdown and flashover.
5.5绝缘电阻:在正常条件下,引线与绝缘外壳之间的绝缘电阻在100mΩ以上。
insulation resistance:≥100mΩ
5.6接触电阻:产品的接触电阻应不大于50mΩ。
contact resistance:≤50mΩ
5.7耐高温试验:产品置于额定动作温度50℃的空气环境中保持96h。
high temperature test:the product is kept in an airenvironment over 50°c for 96 h
5.8耐低温试验:产品置于-40℃空气环境中保持96h。
low temperature test:the product is kept in an airenvironment of -40°c for 96 h
5.9抗振试验:热保护器应能承受振幅1.5mm,频率变化10~55hz,扫描变化周期3~5次/min,
振动方向x、y、z,每个方向各连续振动2h。
anti-vibration test:the thermal protector should be ableto withstand an amplitude of 1.5mm, a frequency change of 10 to55hz, and a scan change period of 3 to 5 times/min.
the vibration directions x, y, and z are continuouslyvibrated for 2 h in each direction.
5.10跌落试验:产品自0.7m高度自由落下1次。
drop test:the product is free to fall from a height of0.7m one time.
5.11抗压试验:产品应能承受100n静压力1min。
compression test:the product should be able to withstand100n static pressure for 1min
5.7,5.8,5.9,5.10,5.11项试验后应满足下列条件:
the additional condition after the 5.7---5.11test.
a. 断开温度变化应在初期值的+7℃以内;
the tolerance of off temp within±7℃
b.接触电阻应在100mΩ以下;
contact resistance≤100mΩ
c.外形应无明显变形;
he shape should be free of obvious deformation
d.导线无开裂损伤。
no cracking damage to the wire
6 寿命 life time
产品在额定电压、电流、功率因数为0.7的条件下,外加热源使其动作4000次,应满足下面条件:
the product is rated at voltage, current and power factorof 0.7.after 4000 cycles action
a断开温度变化应在初始值的+5℃以内; the tolerance of off tempwithin ±5℃.
b接触电阻应在50mΩ以下; contact resistance≤50mΩ.
c继续试验至6000次后能动作;cycle life time over 6000times.
7 其它事项:matters need attention
7.1断开温度检测的升温速率应控制为1℃/1min;
7.1the temperature rise rate for disconnection temperaturedetection should be controlled to 1°c / 1 min
7.2使用过程中产品不能承受强烈冲击力及压迫力;
7.2the product cannot withstand strong impact and pressureduring use.
地址:惠州市博罗县石湾镇明月二路26号3楼 技术咨询李小姐:
8 热保护器动作复位温度参考表action /reset temperaturereference table
序号 item
断开温度 off temp
闭合温度
reset temp
序号 item
断开温度
off temp
30
30±3℃
≥20℃
95
95±5℃
70±15℃
35
35±3.5℃
≥25℃
100
100±5℃
40
40±4℃
≥30℃
105
105±5℃
75±15℃
45
45±4.5℃
≥33℃
110
110±5℃
50
50±5℃
≥35℃
115
115±5℃
80±15℃
55
55±5℃
42±6℃
120
120±5℃
85±15℃
60
60±5℃
45±8℃
125
125±5℃
65
65±5℃
48±10℃
130
130±5℃
90±15℃
70
70±5℃
50±12℃
135
135±5℃
95±15℃
75
75±5℃
53±14℃
140
140±5℃
100±15℃
80
80±5℃
55±15℃
145
145±5℃
85
85±5℃
60±15℃
150
150±5℃
105±15℃
90
90±5℃
65±15℃
155
155±5℃
110±15℃
9 可选配安装支架:optional mounting bracket