美国泰克TCPA400电流探头放大器-

供应商
深圳市美孚科技有限公司
认证
报价
15500.00元每
加工定制
品牌
Tektronix/泰克
型号
TCPA400
联系电话
13554869002
手机号
13530385145
联系人
秦洪立
所在地
深圳市龙岗区坂田街道五和大道永香路华熠科技大厦B座1008
更新时间
2015-07-14 17:04

详细介绍

美国泰克tcpa400电流探头放大器的技术特点:

ac/dc current measurement systems

tcpa300 • tcp312 • tcp305 • tcp303 • tcpa400 • tcp404xl

features & benefitsac/dc measurement capabilitiesdc – 100 mhz, current probe amplifier (tcpa300) uses:dc – 100 mhz, 30 a dc (tcp312)dc – 50 mhz, 50 a dc (tcp305)dc – 15 mhz, 150 a dc (tcp303)

the tcpa300 amplifier, when used with tcp312, tcp305, or tcp303probes, provides a wide range of current measurement capability andspans the gap between low-level milliamp measurements to very highcurrent levels. these three probes provide current measurementcapabilities of 30 a, 50 a, and 150 a dc continuous.for even higher current levels, the tcpa400 amplifier with thetcp404xl current probe measures 500 a dc continuous and750 a dc continuous, derated with duty cycle.

higher frequency performance is available with the tcp312w/tcpa300 providing ≥100 mhz bandwidth and a maximum currentof 30 a dc.

measurement errors and manual calculations are now a thing ofthe past

with this new series of current measurement tools, automaticcontrol and on-screen scaling and units is provided for users oftektronix tds3000, tds500, tds600, tds700, tds5000, tds6000, andtds7000b series oscilloscope systems (the dpo3000, dpo4000, anddpo7000 series oscilloscopes, the tpa-bnc adapter is required).

the tcp300/tcp400 current measurement systems seamlesslyintegrate with your tds series oscilloscope.

even non-tekprobe systems can use the tcpa300/400 series to makeproper current measurements by simply multiplying the measuredoutput voltage on the oscilloscope by the tcpa300/400 series rangesetting.

characteristics
characteristictcp312 w/ tcpa300tcp305 w/tcpa300tcp303 w/ tcpa300tcp404xl w/ tcpa400

bandwidth (–3 db)

dc – 100 mhz

dc – 50 mhz

dc – 15 mhz

dc – 2 mhz*3

rise time

≤3.5 ns

≤7 ns

≤23 ns

≤175 ns

maximum current ratings:

high-current sensitivity range

10 a/v range

10 a/v range

50 a/v range

1 a/mv range

   dc (continuous)

30 a

50 a

150 a

500 a (750 a*4)

   rms (sinusoidal)

21.2 a

35.4 a

150 a

500 a

   peak pulse

50 a

50 a

500 a

750 a

low-current sensitivity range

1 a/v range

5 a/v range

5 a/v range

n/a

   dc (continuous)

5 a

25 a

25 a

n/a

   rms (sinusoidal)

3.5 a

17.7 a

17.7 a

n/a

   peak pulse

50 a

50 a

500 a

n/a

dc accuracy

(operating temp 0 °c to 50 °c)

±3% of reading

±3% of reading

±3% of reading (10 °c to 50 °c)

+3%/–6% of reading (0 °c to <10 °c)

±3% of reading

dc accuracy, typical

(operating temp 23 °c ±5 °c)

±1% of reading

±1% of reading

±1% of reading

±1% of reading

nominal

maximum bare wire voltage

for use with insulated wires only

600 vrmscat i & ii

300 vrmscat iii

lowest measurable current

(at ±3% accuracy at dc)

1 ma

5 ma

5 ma

1 a

scope set to 1 mv/div and 20 mhz bwlimited

scope set to 1 mv/div and 20 mhz bwlimited

insertion impedance

(see curves below)

0.08 ? at 1 mhz

0.15 ? at 10 mhz

0.27 ? at 50 mhz

0.7 ? at 100 mhz

0.035 ? at 1 mhz

0.12 ? at 10 mhz

0.4 ? at 50 mhz

0.01 ? at 1 mhz

0.025 ? at 5 mhz

0.1 ? at 15 mhz

0.1 m? at 10 khz

0.6 m? at 100 khz

8 m? at 1 mhz

16 m? at 2 mhz

typical

maximum amp-second product (based on amplifier rangesetting)

50 a*μs – 1 a/v

500 a*μs – 10 a/v

500 a*μs – 5 a/v

na – 10 a/v

3,000 a*μs – 5 a/v

15,000 a*μs – 50 a/v

na – 1 a/mv

ac-couplinguency bandwidth

(low pass – 3 db point)

<7 hz

displayed rms noise

(at 20 mhz bandwidth limit)

≤250 μarms

≤1.25 marms

≤2.5 marms

≤250 marms

signal delay (delay to output bnc)

17 ns

19 ns

40 ns

80 ns

inputs (probe amplifier)

1

probe open indicator

yes

overload indicator

yes

termination indicator

yes

noncompatible probe indicator

yes

safety certifications

u.s. nrtl listing

ul3111-1

(amplifier)

ul3111-2-032 ; ul3111-1

(probe and amplifier)

canadian certification

can/csa c22.2 no.1010.1

(amplifier)

can/csa c22.2 no.1010.2.032

can/csa c22.2 no.1010.1

(probe and amplifier)

european union compliance

en61010-1/a2

(amplifier)

en61010-1/a2; en61010-2-032

en61010-1/a2

(probe and amplifier)

other

iec61010-1/a2 (amplifier)

iec61010-2-032

iec61010-1/a2

(probe and amplifier)

electromagnetic compatibility

ec council directive 89/336/eec, fcc part 15, subpart b class a,as/nzs 2064.1/2.

power re

(tcpa300/tcpa400 amplifiers)

90 v to 264 v; 47 to 440 hz; 50 w

maximum cat ii (auto switch)

power re (probes)

requires tcpa300 amplifier

requires tcpa400 amplifier

probe model

tcp312

tcp305

tcp303

tcp404xl

warranty

1 year

probe mechanical characteristics

probe cable length

1.5 meters (60 inches)

2 meters (78.7 inches)

8 meters (315 inches)

probe jaw size (max conductor size)

3.8 mm (0.15 inches)

21 mm × 25 mm (0.83 × 1.0 inches)

length

20 cm (7.87 inches)

26.8 cm (10.55 inches)

26.8 cm (10.55 inches)

width

1.6 cm (0.625 inches)

4.1 cm (1.60 inches)

4.1 cm (1.60 inches)

height

3.2 cm (1.25 inches)

15.6 cm (6.13 inches)

15.6 cm (6.13 inches)

weight

0.15 kg (0.33 lb.)

0.66 kg (1.45 lb.)

0.88 kg (1.90 lb.)

tcpa300 and tcpa400 mechanicalcharacteristics

length

17.3 cm (6.8 inches)

width

16.7 cm (6.6 inches)

height

9.14 cm (3.6 inches)

weight

1.14 kg (2.5 lb.)

environmental characteristics

temperature

   operating

0 °c to +50 °c (32 °f to 122 °f)

   nonoperating

–40 °c to +75 °c (–40 °f to 167 °f)

humidity

   operating

5% to 95% r.h. to +30 °c (86 °f)

5% to 85% r.h. +30 °c to +50 °c (86 °f to122 °f)

   nonoperating

5% to 95% r.h. to +30 °c (86 °f)

5% to 85% r.h. +30 °c to +75 °c (86 °f to167 °f)

altitude

   operating

2000 m (6800 ft.) maximum

   nonoperating

12,192 m (40,000 ft.) maximum

*3calculated from rise time.

*4derated w/ duty cycle and frequency.


tcp312 typical peak current frequency derating curve.
tcp312 typical insertion impedance curve.
tcp312 typical specified operating area characteristics.
tcp305 typical peak current frequency derating curve.
tcp305 typical insertion impedance curve.
tcp305 typical specified operating area characteristics.
tcp303 typical peak current frequency derating curve.
tcp303 typical insertion impedance curve.
tcp303 typical specified operating area characteristics.
tcp404xl typical peak current frequency derating curve.
tcp404 typical insertion impedance curve.
tcp404xl maximum current measurement time (750 a at 50 °cambient).
tcp404xl maximum current measurement time (600 a at 50 °cambient).
tcp404xl maximum current measurement time (750 a at 23 °cambient).
(note: at 23 °c ambient, 600 a may be measuredcontinuously with the tcp404xl probe.)

ordering information

probes

productdescription

tcp312

probe; ac/dc current, dc to 100 mhz; 30 a dc (re amplifier)

tcp305

probe; ac/dc current, dc to 50 mhz; 50 a dc (re amplifier)

tcp303

probe; ac/dc current, dc to 15 mhz; 150 a dc (re amplifier)

tcp404xl

probe; ac/dc current, dc to 2 mhz; 500 a dc(750 a dc derated with duty cycle) (requires tcpa400amplifier)

all tcp300/tcp400 current probes include: ac/dccurrent probe, instruction sheet, probe cover, certificate oftraceable calibration.

amplifiers

productdescription

tcpa300

amplifier; ac/dc current probe, dc to 100 mhz, (re or tcp312 or tcp303 probes)

tcpa400

amplifier; ac/dc current probe, dc to 50 mhz, (re probe)

all tcpa300/tcpa400 current probe amplifiersinclude: ac/dc current probe amplifier,instruction/service manual, tekprobe interface cable, male-to-malebnc cable (50 ?), 50 ? feedthrough termination,certificate of traceable calibration.

tcpa300/tcpa400

power plug options

optiondescription

opt. a0

north america power

opt. a1

universal euro power

opt. a2

united kingdom power

opt. a3

australia power

opt. a5

switzerland power

opt. a6

japan power

opt. a10

china power

opt. a11

india power

opt. a12

brazil power

opt. a99

no power cord

language options

optiondescription

opt. l0

english manual

opt. l5

japanese manual

opt. l10

russian manual

opt. l99

no manual

all tcp300/tcpa300/tcp400/tcpa400 series

service options

optiondescription

opt. c3

calibration service 3 years

opt. c5

calibration service 5 years

opt. d1

calibration data report

opt. d3

calibration data report 3 years (with option c3)

opt. d5

calibration data report 5 years (with option c5)

opt. r3

repair service 3 years

opt. r5

repair service 5 years


protective covers.
recommended accessories

accessorydescription

016-1923-00

cover, small probe protective; (for tcp305, tcp312, a6302,a6302xl, a6312, tcp202)

016-1924-00

cover, large probe protective; (for tcp303, tcp404xl, a6303,a6303xl, a6304xl)

016-1922-00

case, transit; current measurement systems

011-0049-02

50 ? feedthrough termination

012-0117-00

50 ? bnc-to-bnc coaxial cable

012-1605-00

tekprobe interface cable, tcpa300 or tcpa400 amplifier to tdsseries oscilloscopes

015-0601-50

current loop, 1 turn, 50 ?, bnc connector (for tcp305,tcp312, a6302, a6302xl a6312, tcp202, tcp303, a6303, a6303xl)

174-4765-00

tcpa300/tcpa400 amplifier calibration adapter

067-1478-00

power measurements deskew fixture, for tcp202, tcp305, tcp312,tcp303, a6302, a6312, a6303, series probes

本产品的加工定制是否,品牌是tektronix/泰克,型号是tcpa400,测量范围是咨询,测量精度是0.5,产品用途是电流探头