西门子840D和控制器通讯不上(报警120202故障)维修

供应商
上海涌迪工业自动化有限公司
认证
联系电话
18321155129
手机号
18721658859
联系人
何工
所在地
上海市青浦区新府中路1536弄6号612
更新时间
2025-04-29 07:02

详细介绍

西门子840d和控制器通讯不上(报警120202故障)维修,报警120201通讯故障维修,2001故障维修,120202故障,nc/plc未链接维修,故障810004故障停止/中断事件,2120警号故障,nck风扇报警,ncu数码管显示1,ncu数码管显示3,ncu数码管显示4,ncu数码管显示8,ncu数码管没有显示,ncu数码管不亮,ncu指示灯全亮,西门子840d的,840dsl显示150202等待nck连接报警,西门子840dncu跳电显示3不启动维修,突然a轴出现报警:25040,25201,300608,700008等报警,ncu风扇报警2120维修,西门子nuc下程序报错,西门子840dsl数控系统报警150202等待与nck的连接报警,810d总控制器无显示维修,西门子840d系统300608合21612报警,ncu显示111故障,西门子840d报警400260维修,840d加工中心报300500维修,西门子840d系统报警120202通讯故障,ncu上电就显示8,西门子ncu风扇不转,ncu数字走到2就显示108了,ncu显示3,ncu数码管循环显示0、1、6右边一排灯全亮,第二天无显示指示灯不亮,nck风扇故障2120,关机2天程序丢失,数码管循环显示109,数码管不亮,西门子ncu报113故障,ecu红灯plc停止故障,左边指示灯全亮显示106,plc下程序报错误清单不能复位plc内存,840d驱动控制器显示0,ncu上面2排灯全亮数码管不亮故障,840d龙门镗床300201报警,ncu左边灯全亮右边灯闪烁,数码管显示116,ncu数字显示135,故障代码2120nck风扇故障维修上电一会数码管显示个小数点,ncu上面显示数字1不动,ncu通讯端口连接不上不通讯,西门子840dsl数控系统显示150202故障维修,等待与nck的连接

ncu573.4 6fc5357-0bb34-0ae1

ncu571.5 6fc5357-0bb15-0aa0

ncu572.3 6fc5357-0bb23-0aa1

ncu573.3 6fc5357-0bb33-0ae2 

ncu573.3 6fc5357-0bb33-0aa0 

ncu573.3 6fc5357-0bb33-0aa1 

ncu572.2 6fc5357-0bb52-0ae0 

ncu572,5b 6fc5357-0bb25-0ab0 

ncu 573.5 6fc5357-0bb35-0aa0

ncu 572.2 6fc5357-0bb21-0ae1

6fc5247-0aa00-0aa2 ncu-box

ncu 571.4 6fc5357-0bb12-0ae0

ncu571.4 6fc5357-0bb14-0aa0 

ncu571.3 6fc5357-0bb13-0aa1

ncu571.5 6fc5357-0bb15-0ab0 

ncu572.3,6fc5357-0bb22-0ae0

ncu571.5 6fc5357-0bb15-0aa0

ncu 571.5 6fc5357-0bb15-0aa0

ncu 572.2 6fc5357-0bb21-0ae0

ncu 571.2 6fc5357-0bb11-0ae0

ncu571 6fc5357-0ba10-0ae0

6fc5357-0bb25-0aa0 ncu572.5

ncu720.3 6fc5370-0aa30-0aa1 

ncu571.5 6fc5357-0bb15-0aa0 

ncu573.2 6fc5357-0bb25-0aa0 

ncu572.2 6fc5357-0bb21-0ae0

ncu571.3 6fc5357-0bb11-0ae1

ncu572.4 6fc5357-0bb23-0ae0

ncu571.3 6fc5357-0bb13-0aa0

ncu573 6fc5357-0by32-0ae1

ncu730.26fc5373-0aa00-0aa1

ncu710.3 6fc5371-0aa30-0aa1

ncu572.5 6fc5357-0bb25-0aa0

ncu573.5 6fc5357-0bb35-0aa0

ncu572.4 6fc5357-0bb24-0aa0

ncu573.3 6fc5357-0bb33-0ae2

ncu573 6fc5357-0by30-0ae0

ncu571.3 6fc5357-0bb11-0ae1

 ncu573.5 6fc5357-0bb35-0ab0

nc572.46fc5357-0bb24-0aa0

ncu573 6fc5357-0by33-0ae0

ncu571.2 6fc5357-0bb11-0ae0

ncu571.46fc5357-0bb14-0aa0

ncu573.5 6fc5357-0bb35-0ae0

ncu571.5 6fc5357-0bb15-0aa0

ncu571.5 6fc5357-0bb15-0aa0

ncu573.2 6fc5357-0bb33-0ae1

ncu573.2 6fc5357-0bb31-0ae0

ncu571.3 6fc5357-0bb11-0ae1

ncu 572.3 6fc5357-0bb23-0aa0

ncu573.36fc5357-0bb33-0ae3

ncu 572.3 6fc5357-0bb22-0ae0

ncu 573.2 6fc5357-0bb33-0ae0

6fc5357-0bb11-0ae1 ncu571.3

ncu -box 6fc5247-0aa00-0aa3

ncu572.3 6fc5357-0bb22-0ae0

ncu573.4 6fc5357-0bb34-0ae0 

 ncu573.4 6fc5357-0bb34-0ae1

 ncu573.5 6fc5357-0by31-0ae0

西门子802d系统恢复出厂设置方法

  802d系统长时间停用再次启用时,在启动过程中,执行到系统检测时出现死机,无法进入操作界面,可按以下步骤恢复

  1:在操作键盘用到4个软键,分别为屏幕下侧*个、第三个、第十个和屏幕右侧从上数第二个软键,

  2:系统送电,屏幕出现显示时开始,按顺序依次按下

  软键,然后等待。

  3:大约1分钟左右,显示屏中央出现是否按缺省模式启动,

  这时按下软键,系统可以正常启动了。画面正常。

  4:系统画面正常后,plc的工作和监控还不正常,表现为t64信号无法输出,驱动器显示a831报警,其实这时总线没有问题。需要由802d主画面选择调试界面,执行按存储数据启动。

  执行完以上操作后,你的系统就完全恢复了。可见及时保存数据和程序还是很有必要的


840D通讯报警,840D报120202,840D报2001故障,840D报810004,840D报PLC没启动
展开全文
我们其他产品
我们的新闻
相关产品
控制器 西门子plc 通讯 西门子低压电器 rgb控制器 DMX控制器 西门子工控机 上门电脑维修 伸缩门控制器 PH控制器 西门子可编程控制器
在线询价 拨打电话