ISTA-2B 国际安全运输协会 2B测试
- 供应商
- 深圳市实测通技术服务有限公司
- 认证
- 测试周期
- 5-7天
- 寄样地址
- 深圳宝安
- 价格费用
- 电话详谈
- 联系电话
- 17324413130
- 罗工
- 17324413130
- 检测工程师
- 罗卓文
- 所在地
- 深圳市罗湖区翠竹街道翠宁社区太宁路145号二单元705
- 更新时间
- 2024-05-20 20:00
transportation test (ista2b)
as perista integrity test procedure 2b: 2011, the performance andintegrity of the packaged product was evaluated.
numberof sample tested: one (1) carton
1.shipping mark: nil / (see enclosedpicture )
2.description of package:
(see enclosedpicture 1)
3. testprocedure
(a)anticipated conditioning: [internal use: the conditionfor test must confirm with cso]
(i)preconditioning: laboratory ambient temperature and humidity forsix (6) hours at : _______°c; _______% rh.
(ii) extremecold, uncontrolled rh (72) hours at: -29°c/
cold, humid (72)hours at: 5°c, 85% rh/
controlledconditions (72) hours at: 23°c, 50% rh/
hot, humid (72)hours at: 38°c, 85% rh/
hot, humid thenextreme heat, moderate rh: (72) hours at: 38°c, 85% rh and then forsix (6) hours at 60°c, 30% rh/
elevatedtemperature, uncontrolled rh (72) hours at: 50°c/
extreme heat,dry (72) hours at: 60°c,15% rh/
severe cold,uncontrolled rh (72) hours at: -18°c
userdefined ____________________________________________.
result:
no visiblechange was found on the contents of the packagedproduct.
(b)compression test :
compression testsystem: apply and release test force .
test force:______ pounds.
thepackaged-product may be notwarehoused in astacked.
compensatingfactor f=
total number ofpackaged-products in a stacks= (as claimed byapplicant /as recommended by standard.)
[internal use:the no.(s) was not warehoused in a stack mustconfirm with cso; s= ,f= ,wt= ,test
force=[wtx(s-1)xfx1.4] ( f=5 if the packaged-product may be warehoused , otherwisef=4)
remark: no puncture ofcarton box was observed.
(c)vibration test (first part)
mode ofvibration: vertical linear.
uency: ________ cpm.
duration oftesting: ________minutes and ________seconds.
number ofimpacts: 11,800.
remark:no puncture ofcarton box was observed.
(d)impact and rotational edge drop test
(a) notto shock the top surface
theuence and orientation were listed as below:
thesequence was listed as below:
remark:no puncture ofcarton box was observed.
(b)shock the top surface
the drop se orientation were listed as below:
(e)vibration test (second part)
mode ofvibration: vertical linear.
uency: __________cpm.
duration oftesting: _________minutes and ________seconds.
number ofimpacts: 11,800.
remark: nopuncture of carton box was observed.
4.interior packaging:
sample for reference参考图片:
<div font-size:12px;white-space:normal;"="">sample report报告样本:
展开全文